Table 4-14: PostScript Emulation Device Parameters
Key
Type
Device Parameters for the Communication Device %Parallel%, %ParallelA%, %ParallelB%, %ParallelC%, %ParallelD%
(%Parallel_NV% and %Parallel_Pending% contain the same parameters)
DelayedOutputClose
boolean
Enabled
boolean
Filtering
name
Handshake
integer
HasNames
boolean
Interpreter
name
On
boolean
OutputDevice
string
PCLSmartSwitch
boolean
PortLocation
string
Definition
Selects how the printer manages the port at the end of each print job. Supported values are:
True
An end-of-file message is not sent until the current job and all preceding jobs
finish printing.
False
An end-of-file message is sent as soon as a job finishes executing in the
interpreter, whether or not that job has finished printing.
This value is set independently for each port.
(Read-only)
Supported values are:
True
False
Indicates if the input needs further filtering before the data can be correctly processed.
Supported values are:
InterpreterBased
None
(Read-only) Always returns a value of 2.
(Read-only) Always returns False.
(Read-only)
Supported values are:
PostScript
AutoSelect
PCL
PPDS
Designates if the communication channel is On and able to receive and send data.
Supported values are:
True
Data is sent and processed
False
Data is lost
(Read-only)
Supported values are:
True
PCL SmartSwitch
False
PCL SmartSwitch
For more information, see "Using SmartSwitch" on page 2-1.
(Read-only) Designates the physical location of the port related to the parameter set.
Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
Option Slot 4
4-81
is set to
.
On
is set to
.
Off