Page 1
(11) Positioner control pattern (TAD) EL TV Y : C3771BE / C3604BD A : SHUT by 4 mA « OPEN by 20 mA T : SCS13A / SUS304 B : SHUT by 20 mA « OPEN by 4 mA (3) Voltage...
Note) C3771BE (PLTD) / C3604BD (PLTD) PRESSURE & TEMPERATURE RATING The optional for steam fluids. Valve type Option code O-ring Replace (Steam resistant FKM) A / E (Brass) E (Stainless) INHERENT FLOW CHARACTERISTIC A / AE E / EG Cv value (%)
Page 3
Valve opening (%) Valve opening (%) Valve opening (%) Range ability 20:1 Range ability 20:1 FLOW PATHS (Position / P1) (Position / P2) Note) When a closed path is exposed to high pressure, it may leak slightly to an open path. 3/11...
Page 4
0.08 0.19 0.35 (round-trip) Operation time [s] Less than 1. Operation SHUT by air to port A. « OPEN by air to port B. Air pressure 0.4 to 0.7 MPa Piping connection Rc 1/8 Method of operation Scotch yoke Housing material PPS resin Ambient temperature -10 to 50 °C (Please be careful when you use in 5 °C or less, so that there no freeze.)
Page 5
0.11 0.18 0.34 0.66 1.36 2.72 5.56 (round-trip) Operation SHUT by air to port A. « OPEN by air to port B. Air pressure 0.4 to 0.7 MPa Piping connection Rc 1/8 Rc 1/4 Method of operation Rack-and-pinion Scotch yoke...
OSPEX225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position OPTIONAL PARTS Classification Code PND PSO PSC TAD TAO TAC Speed Controller with bypass valve (Housing material: PPS) FR Unit (Regulator with Filter) TA2-FR (KONAN) Limit Switch Box (Standard load signal) Explosion Proof Limit Switch / VCX7001 (azbil) Ex d e II C T6 Speed Controller (with One-touch Fitting) One set...
Page 7
OSPEX225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position SOLENOID VALVE (Applicable Pneumatic Actuators: PND-05D / TAD / TAO / TAC) Classification ( : Voltage code) Code 5-port Lead wire 4N3S102K-L N43SL : Voltage Solenoid Valve 1 : 100V AC DIN Connector 4N3S102K-D...
If possible, store in the original package. appropriate shielding plate. • Do not remove a dust proof cap until the piping. • If there is a possibility that the fluid and drive part CHECKING freeze, please take measures to prevent freezing.
TESTING MAINTENANCE After piping, check following points. • Do the routine maintenance at least once in half a • Piping is correct. year. • Air or fluid leakage from connection. Flow • Do not set or take spring unit parts apart after direction of air is correct.
Supply air. operate. come out. Air pressure is Adjust to standard too low. pressure level. Stop in the • Biting of Remove a foreign valve seat. object. position. • The scale has adhered to the valve ball. Leakage • Valve cap get Replace the valve.
Need help?
Do you have a question about the A and is the answer not in the manual?
Questions and answers