GENERAL

This series is suitable for main or bypass valve in piping system.
The position of manual handle can be changed.
Manual operation
Valve only
Lever
Gear
Valve
BR type For various fluids and general use.
BS type For Wafer.
VR type For control.
TR type For mixing / dividing.
LR type For mixing / dividing.
T3 type Trunnion structure. (with flow paths)
L3 type Trunnion structure.
PRODUCT CODE
BR type
(JIS 10K)
(JIS 20K)
BS type
(Full port)
(Standard port)
VR type
(V-port)
(Reduced port)
TR type
LR type
T3 type
L3 type
(1) Actuator
MAX
(2) Valve
BR BS VR
TR LR
T3 L3
(3) Operation
0 : (Zero) Valve only
L : With manual lever
G : Gear
Instruction manual
MAX SERIES Ball Valve
M A X B R
-
M A X B R
-
M A X B S
-
M A X B S
-
M A X V R
-
M A X V R
-
M A X T R
-
M A X L R
-
M A X T 3
-
M A X L 3
-
(1)
(2) (3) (4) (5) (6) (7) (8)
(4) Sizing code
- : Hyphen
(5) Connection
1 : JIS 10K
3 : JIS 20K
(6) Body material
T : SCS13A
U : SCS14A
(7) Ball material
T : SUS304 / SCS13A
U : SUS316 / SCS14A
BR BS VR TR LR T3 L3
BR VR
TR
1
-
3 T T
-
1
-
1
R
1 U U
-
1 U U
R 0 1 5 -
1 T T P -
1 T T P -
1 T T G -
1 T T G -
(9)
(8) Seat material
F : F-PTFE
G : R-PTFE
R : R-F-PTFE
P : R-PTFE
(9) Size [mm]
ex. 25 A ® 025
1/7
OSYBR225-EN
BS
LR
T3 L3
-
-
-
-
-
-
-
-
-
-
(10)
(11)
(10) Option
ST : Seat for abnormal
pressure rise
(11) Flow paths
a to d : T3 type
SP-1474

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for VPro MAX Series

  • Page 1 OSYBR225-EN Instruction manual MAX SERIES Ball Valve BR BS VR TR LR T3 L3 SP-1474 Please read this manual before installation and use. GENERAL This series is suitable for main or bypass valve in piping system. The position of manual handle can be changed.
  • Page 2 OSYBR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Full port 2-way, Wafer 2-way, V-port Connection JIS10K Flanged-end JIS20K Flanged-end JIS Flanges 10K JIS10K Flanged-end Fluid Max pressure 1 MPa 2 MPa 1 MPa 1 MPa Size [mm]...
  • Page 3 OSYBR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type TR / LR T3 / L3 Design 3-way, Full port 3-way, Full port Connection JIS10K Flanged-end JIS10K Flanged-end Fluid The optional for steam fluids. Max pressure 1 MPa 1 MPa...
  • Page 4 OSYBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS MANUAL LEVER DIMENSIONS HANDLING OF MANUAL LEVER CASTING LEVER Attention • The lever handle is removed and shipped. • The lever mounting direction can be changed in units of 45 degrees. • Do not apply excessive torque to the lever. •...
  • Page 5 OSYBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS GEAR DIMENSIONS OPEN SHUT φK Handle Valve size [mm] Gear handle [mm] Actuator MAG-F07 MAG-F10 MAG-F12 HANDLING OF GEAR • The handle wheel of the gear is removed and shipped. • Insert the handle into the gear shaft. •...
  • Page 6 OSYBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HANDLING & STORAGE TIGHTEN THE GLAND NUTS (T3 / L3) HANDLING • Check that there is no leakage from the gland Do not drop or throw the product as it may break. packing. STORAGE •...
  • Page 7 OSYBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TROUBLESHOOTING Problem Cause Solution Stop in the • Biting of Remove a foreign mid position. valve seat. object. • The scale has adhered to the valve ball. Leakage • Valve cap Replace the valve. from get loose.

This manual is also suitable for:

BrBsVrTrLrT3 ... Show all

Table of Contents