VPro SR Instruction Manual

Pneumatic actuated ball valve
Hide thumbs Also See for SR:

Advertisement

Quick Links

Please read this manual before installation and use.
GENERAL
Threaded-end ball valve with pneumatic actuator.
Actuator
Double-acting type
PND
TAD
Single-acting type
PSO (Airless SHUT)
TAO (Airless SHUT)
PSC (Airless OPEN)
TAC (Airless OPEN)
PRODUCT CODE
SR type
SH type
MS type
MV type
(V-port)
(Reduced port)
MH type
H
type
HH type
ST type
SL type
(1) Actuator
(5) Connection
PND TAD
5 : Threaded End Rc
PSO TAO
PSC TAC
(6) Body material
U : SCS14A / SUS316Ti
(2) Valve
S : Carbon steel
SR SH
MS MV
(7) Ball material
MH
U : SCS14A / SUS316
H
HH
ST SL
(8) Seat material
T : PTFE
(3) Voltage
F : F-PTFE
9 : Air
P : R-PTFE
D : POM
(4) Sizing code
R : R-F-PTFE
0 : Standard
1 : Light
(9) Size [mm]
2 : Heavy
ex. 25 A ® 025
Pneumatic Actuated Ball Valve
Valve
SR type For food / Corrosive fluid.
SH type For high temp. (up to 2 MPa)
MS type 3 piece / For heavy load.
MV type 3 piece / For control.
MH type 3 piece / For high pressure.
H
type For high pressure.
HH type For ultra-high pressure.
ST type 4 seats, 3 way. (with flow paths)
SL type 4 seats, 3 way.
S R 9
S H 9
M S 9
M V 9
M V 9
M H 9
H - 9
H H 9
S T 9
S L 9
(1)
(2) (3) (4) (5) (6) (7) (8)
(10) Option
(11) Positioner control pattern (TADMV)
(11) Positioner control pattern (PSOMV / TAOMV)
(11) Positioner control pattern (PSOMV / TAOMV)
(11) Flow paths
Instruction manual
SR SH MS MV MH H HH ST SL
5 U U T -
5 U U F -
5 U U P -
5 U U P -
5 U U P R
5 U U
-
5
U D -
5 S U D -
5 U U F -
5 U U F -
(9)
FR : Filter Regulator Unit
LB : Limit Switch Box
EP : Positioner
EX : Smart Positioner
ES : Smart Positioner
ER : Smart Positioner
A : SHUT by 4 mA « OPEN by 20 mA
B : SHUT by 20 mA « OPEN by 4 mA
C : OPEN by 20 mA « SHUT by 4 mA (Airless SHUT)
D : OPEN by 4 mA « SHUT by 20 mA (Airless SHUT)
E : SHUT by 4 mA « OPEN by 20 mA (Airless OPEN)
T : SHUT by 20 mA « OPEN by 4 mA (Airless OPEN)
a to d : ST type
1/14
OSPSR225-EN
SR
SH
MS / MV / MH
H / HH
-
-
-
-
-
-
-
-
-
-
-
-
-
(10)
(11)
SP-1474
ST / SL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR and is the answer not in the manual?

Questions and answers

Summary of Contents for VPro SR

  • Page 1 OSPSR225-EN Instruction manual Pneumatic Actuated Ball Valve SR SH MS MV MH H HH ST SL SP-1474 Please read this manual before installation and use. GENERAL Threaded-end ball valve with pneumatic actuator. Actuator Valve Double-acting type SR type For food / Corrosive fluid.
  • Page 2: Pressure & Temperature Rating

    OSPSR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Full port 2-way, Full port Connection Threaded End Rc Threaded End Rc Fluid Max pressure 2 MPa 1.4 MPa 2 MPa Size [mm] 015 to 020 025 to 040 015 to 032...
  • Page 3 OSPSR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Full port 2-way, V-port (Reduced port) 2-way, V-port Connection Threaded End Rc Threaded End Rc Fluid Max pressure 3.5 MPa 2.4 MPa 2 MPa Size [mm] 010 to 025...
  • Page 4 OSPSR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Full port Connection Threaded End Rc Fluid Max pressure 14 MPa 10 MPa 7 MPa 5 MPa Size [mm] 010 to 020 025 to 040 010 to 020 025 to 040...
  • Page 5 OSPSR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type H (Carbon steel) H (Stainless) Design 2-way, Full port 2-way, Full port 2-way, Full port Connection Threaded End Rc Threaded End Rc Threaded End Rc Fluid Max pressure 31.5 MPa...
  • Page 6 OSPSR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type ST / SL Design 3 way, Standard port Connection Threaded End Rc Fluid Max pressure 1 MPa Size [mm] 015 to 032 Material Body SCS14A Ball SCS14A...
  • Page 7 OSPSR225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position PND type Classification Double-acting type Actuator type PND-03S PND-03D PND-04D PND-05D Weight [kg] 0.2 Air consumption 0.05 0.08 0.19 0.35 (round-trip) Operation time [s] Less than 1. Operation SHUT by air to port A.
  • Page 8 OSPSR225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position TAD type Classification Double-acting type Actuator type TAD-040 TAD-050 TAD-063 TAD-080 TAD-100 TAD-125 TAD-160 Weight [kg] 0.9 18.2 Air consumption 0.11 0.18 0.34 0.66 1.36 2.72 5.56 (round-trip) Operation...
  • Page 9: Optional Parts

    OSPSR225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position OPTIONAL PARTS Classification Code PND PSO PSC TAD TAO TAC Speed Controller with bypass valve (Housing material: PPS) FR Unit (Regulator with Filter) TA2-FR (KONAN) Limit Switch Box (Standard load signal) Explosion Proof Limit Switch / VCX7001 (azbil) Ex d e II C T6 Speed Controller (with One-touch Fitting) One set...
  • Page 10 OSPSR225-EN PNEUMATIC ACTUATOR SPECIFICATIONS 3 way valve: SHUT / Position , OPEN / Position SOLENOID VALVE (Applicable Pneumatic Actuators: PND-05D / TAD / TAO / TAC) Classification ( : Voltage code) Code 5-port Lead wire 4N3S102K-L N43SL : Voltage Solenoid Valve 1 : 100V AC DIN Connector 4N3S102K-D...
  • Page 11 OSPSR225-EN PNEUMATIC ACTUATOR SPECIFICATIONS DIMENSIONS Actuator PND-03S PND-03D PND-04D PND-05D 03D ~ 05D Actuator N N1 PSO-03S PSC-03S 65 109 54 30 PSO-03D PSC-03D 73 165 54 30 PSO-04D PSC-04D 90 190 67 36 PSO-05D PSC-05D 98 247 82 44 PSO-05W PSC-05W 98 288 95 48 03D ~ 05W Actuator...
  • Page 12: Installation

    OSPSR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HANDLING & STORAGE ENVIRONMENT HANDLING • Do not install in place where corrosive gas is present Proper care in handling the valve should be taken to or where vibration is heavy (0.5 G or more). prevent damage.
  • Page 13: Operation

    OSPSR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS OPERATION MANUAL OPERATION AIR SOURCE • Double-acting; stop the air supply and do not leave • Use the filtered dry air (less than 40 ). the air inside of cylinder. • Extra attention is needed where it's cold climate •...
  • Page 14: Troubleshooting

    OSPSR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TROUBLESHOOTING Problem Cause Solution Fail to Air doesn't Supply air. operate. come out. Air pressure is Adjust to standard too low. pressure level. Stop in the • Biting of Remove a foreign mid position. valve seat.

This manual is also suitable for:

ShMsMvMhHHh ... Show all