Installation and maintenance instructions
3-9008-011
5.2

3" through 24" PT Meter assembly

MECHANICAL EQUIPMENT DAMAGE
See Section 7 "INSPECTION" prior to assembly.
Failure to properly clean and inspect all parts according to Section 7 "INSPECTION" may
result in meter damage and improper operation.
Procedure
1. If rimmed rotor meter, install deflector ring by sliding it, widest edge first, into
2. Insert angled end of hanger blades into the three slots in a hanger hub. When
Installation and maintenance instructions
CAUTION
upstream end of meter housing until contacting the step in the bore.
Note
Rimless rotor meters do not have a deflector ring.
Figure 5-17: Step 1
correctly installed outside hanger blade edges are parallel to hanger hub. The
upstream and downstream edges are perpendicular to hanger hub.
Figure 5-18: Step 2
Disassembly and assembly instructions
October 2019