Dimensions and specifications
October 2019
Viscosity
High viscosities will reduce flow range of meter. Consult Daniel Measurement engineers.
Pickup Coil
Nominal open circuit peak to peak voltage output:
Minimum flow
Maximum flow
Table 1-2: Materials of construction
Item
Meter Body
Flanges (Slip on)
Suspension
Rotor Blades (Rim Type)
Rotor Blades (Blade Type)*
Sleeve Bearings
Journal Bearings
Rotor Hub
Rotor Rim
Rim Buttons
Cones
Shaft
* Recommended for salt water service; blade type meters with 316SS body, 316SS suspension,
316SS cones and Nickel 200 blades.
† No option available.
Note
Consult Daniel engineers for unique applications.
16
Installation and maintenance instructions
BLADE
4.0v
0.3v
Standard
304SS
Carbon Steel
304SS
304SS
430SS
Cemented Tungsten
Carbide
Cemented Tungsten
Carbide
1"-6"
430SS
8"-12"
430SS
16"-24"
430SS and 7075AL
2"-4"
316SS
6"-24"
304SS
Hi Mu 80
304SS
17-4 PH Heat Treated Stainless Steel
3-9008-011
RIMMED
5.0v
0.1v
Optional
316SS
304SS or 316SS
316SS
316SS
Nickel 200*
316SS or 304SS
430SS and 7075AL
316SS
316SS