Specifications .....................4-5 Instrument Description .................. 6 Display Description ..................6 Operating Instructions ................7-15 Setting up the R9920 ................7 Power ON/OFF ..................7 Main Operating Modes (Live and Data logging) ........7-8 Live Mode ................... 7 Data Logging Mode ................7 Screen Saver Mode ................
Introduction Thank you for purchasing your REED R9920 Indoor Air Quality Meter. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service. Product Quality...
While the meter is off, slide the temperature and humidity sensor directly onto the cradle jack. Note: The R9920 can be mounted on a wall using the supplied wall mount bracket and screws. Mount the bracket on the wall first and then snap the meter onto the bracket.
Screen Saver Mode When the R9920 is idle for 60 seconds, the screen saver activates as shown below. Simply tap on the screen to return to the main interface screen. Setup Mode Tap the MENU button on the Main Interface Screen to enter Setup Mode.
To set a recording start time, open the interactive calendar by tapping the small arrow to the right of the programming field. (Scheduled recording must be enabled) Note: The default start time is the current system date and time. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
Page 10
Tap SAVE to confirm your settings or tap on the X to cancel and resume normal operation. Note: At any time, you can tap on the X to exit the Setup mode and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
"Sort by value" for temperature, humidity and CO Note: At any time, you can tap on the X to exit the Setup mode and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
To delete all files, tap the check box located next to "All", and then tap DELETE. Note: At any time, you can tap on the X to exit the Setup mode and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
When active, the screen-saver mode appears as shown below, providing real-time relative humidity, air temperature, and CO levels. Note: At any time, you can tap on the X to exit the Setup mode and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
Set the required time format by tapping on the circle next to "12-Hour" or "24-Hour" format. Note: At any time, you can tap on the X to exit the Setup mode and resume normal operation. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
Data Upload Connect the R9920 via the included cable to a USB port on your PC, to download the recorded data files. The R9920 saves recorded data to a CSV (Excel) in the RH-T Data folder. Once connected, the PC will recognize the R9920 as a USB storage device.
Charging the Battery Connect the R9920 via the included cable to a USB port on your PC or into a wall outlet using the included USB Power Adapter to charge the Li-ion battery. Note: Charge the meter until the battery indicator appears full and remove the charging cable when done.
REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance.
Page 18
TEST & MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS! www.REEDInstruments.com REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
Need help?
Do you have a question about the R9920 and is the answer not in the manual?
Questions and answers