Configuring the Slave Exciter

The Slave Exciter cannot be configured by the WanderGuard BLUE Manager. It
needs to be configured by the Local Engine. The configuration includes:
Setting the LF range of the Exciter.
Setting the Exciter to the Slave Exciter.
Do the following to configure the Slave Exciter:
1. Set the PC with AeroScout Location Engine:
Install Engine 5.0 SP4 Manager and Server (Non-Cisco Platform).
Connect the PC to the 'LAN' Connection of the Exciter.
Set the PC to have static IP of the same subnet as the Exciter.
The Exciter default IP address is 192.168.1.178.
User and Deployment Guide
36