ALARM MODE
When not in Night Mode, Relay 2 gets activated when the door is
opened and there is TIF.
When in Night Mode, Relay 2 gets activated when the door is opened.
Relay 2 returns to default when the Controller receives Reset or Bypass
code from the Keypad.
After Reset:
In Night Mode, if the door is opened, the Controller switches back
to Alarm Mode.
In Day Mode, if the door is opened and there is TIF, the Controller
switches to Alarm mode.
ALARM RESET
Reset code returns Relay 2 to its default setting (pending door status).
Reset code returns Relay 1 to its default setting (pending door status).
If there is an alarm condition (e.g., Night Mode with open door, open
door and TIF), the alarm reset does not reset the alarm.
If there is "Alarm In", the alarm Reset resets it.
OVERRIDE MODE
Relays 1 and 2 are deactivated.
LF transmission is disabled.
Any person with or without Tags can go through the door during the
Override period.