Stanley Healthcare WanderGuard BLUE User Manual page 32

Wander management solution
Hide thumbs Also See for WanderGuard BLUE:
Table of Contents

Advertisement

VISITOR MODE
When the Visitor code is entered in the Keypad, relay 1 is set to
deactivated state.
When the Visitor code is entered in the Keypad, relay 2 is set to
deactivated state.
Visitor mode uses the Bypass time out period.
During the Bypass timeout period, multiple people without Tags
are allowed to walk through the door
If there is TIF during Visitor mode and door is open, relay 2 is
activated.
Visitor is terminated if the door is not opened 5 seconds after the
visitor code is entered.
Within the Bypass time out period, Visitor mode is terminated after
the door is closed.
After Bypass timeout:
In Night Mode, if the door is opened, the Controller switches to
Alarm Mode
In Day Mode, if the door is opened and there is TIF, the Controller
switches to Alarm Mode
Visitor code does not reset the alarm.
If 'alarm in' or TIF, the Controller switches to Visitor Mode when the
Visitor code is entered and relay 1 gets deactivated.
User and Deployment Guide