4.5.5

Advanced Iris Controls

Figure 33.
Iris Max Voltage
This sets the maximum voltage that will be applied to the iris motor. The range is 0V to 9V.
Iris Coarse Step
This sets the voltage that gets applied to the iris motor when the coarse Iris control is activated. It is specified
as a percentage of the Iris Maximum Voltage
Iris Fine Step
This sets the voltage that gets applied to the iris motor when the fine Iris control is activated. It is specified as
a percentage of the Iris Maximum Voltage