Zeiss MCU 2008 Operating Manual
Zeiss MCU 2008 Operating Manual

Zeiss MCU 2008 Operating Manual

Two-axis stage controller

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Zeiss MCU 2008

  • Page 2 References to products of other manufacturers are provided for information only. They are not intended to express an approval or recommendation for use of such products. Carl Zeiss Microscopy GmbH will not assume any liability as to the performance or the use of this type of products.
  • Page 3: Table Of Contents

    Service .......................... 16 PROPERTY RIGHTS ..................... 17 ILLUSTRATIONS Fig. 1-1 Warning and information labels on the rear side of MCU 2008 ..........7 Fig. 2-1 View of unit, front (right), back (left), and operating elements ........... 10 Fig. 2-2 Joystick ..........................11 Fig.
  • Page 4: Introduction

    NOTE This symbol indicates a note that should be closely followed. The MCU 2008 must not be used for purposes other than those described in this operating manual. The operating instructions of the microscope used have to be observed. M60-2-0019 e 05/2012...
  • Page 5 Carl Zeiss Particular attention must be paid to the following notes: The MCU 2008 is not equipped with any special devices for protection from substances that are corrosive, potentially infectious, toxic, radioactive, or otherwise hazardous to health. Make sure to observe all legal regulations, particularly the relevant national accident prevention regulations when handling such substances.
  • Page 6 There is a crush hazard and hands may be injured when positioning the stage by means of the MCU 2008 controller. The MCU 2008 can be used for voltages ranging from 100 to 240 V ±10 %, 50 to 60 Hz, without any necessity of additional change of instrument voltage setting.
  • Page 7: Warning And Information Labels

    INTRODUCTION MCU 2008 Warning and Information Labels Carl Zeiss Warning and Information Labels Fig. 1-1 Warning and information labels on the rear side of MCU 2008 M60-2-0019 e 05/2012...
  • Page 8: Notes On Warranty

    Except for action which is explicitly described in this operating manual, no maintenance or repair work may be performed. Repairs may only be carried out by Carl Zeiss service staff or specifically authorized persons. Should any malfunction occur, please get in touch with the Carl Zeiss microscopy service in Germany (see page 16) or your local Carl Zeiss agency.
  • Page 9: Instrument Description

    The MCU 2008 supersedes the MCU 28. Usable Stages Only DC scanning stages tested by Carl Zeiss Micro Imaging GmbH are allowed to be used. All DC stages operated by the customer in combination with the MCU 28 will also run with the new controller.
  • Page 10: View Of Unit And Operating Elements

    INSTRUMENT DESCRIPTION Carl Zeiss View of Unit and Operating Elements MCU 2008 View of Unit and Operating Elements ON/OFF switch Power connection with fuse compartment Port for X axis of DC XY scanning stage Port for Y axis of DC XY scanning stage...
  • Page 11: Functional Description

    Functional Description Carl Zeiss Functional Description The MCU 2008 is a 2-axis motor controller for DC scanning stages equipped with a disk encoder on the motor axis. The joystick (432903-9902) can be acquired to be used as operating element. The controller is provided with two CAN bus ports and a USB port.
  • Page 12: Technical Data

    Technical Data MCU 2008 Technical Data Dimensions (width x depth x height) MCU 2008 ..................approx. 250 mm x 220 mm x 100 mm Weight MCU 2008 ........................approx. 2.5 kg Joystick ..........................approx. 0.4 kg Mechanical stage ......................approx. 4.0 kg...
  • Page 13: Installation

    INSTALLATION MCU 2008 Connecting the MCU 2008 Carl Zeiss INSTALLATION Connecting the MCU 2008 Power connection with fuse compartment Port for X axis of DC XY scanning stage Port for Y axis of DC XY scanning stage Port for joystick...
  • Page 14: Operation

    • Press the switchover knob (4-2/1) integrated in the operator level in order to change the speed mode "slow" or "fast". If the MCU 2008 is run in connection with the motorized microscope Axio Imager Axio Observer, it is possible to set for each objective separately a factor for individual adap- tation of the speed ranges "slow"...
  • Page 15: Maintenance, Fuse Change, And Service

    MAINTENANCE, FUSE CHANGE, AND SERVICE Maintenance Before cleaning the MCU 2008 it is imperative to disconnect the power plug. • The MCU 2008 must be cleaned using a slightly moistened, not dripping cloth. No moisture must get into the instrument. Fuse Change...
  • Page 16: Service

    All repairs of mechanical, optical or electronic components inside the units may only be performed by service staff or specially authorized personnel. When service is required, please get in touch with your regional representative or with Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena, Germany microscopy@zeiss.com...
  • Page 17: Property Rights

    PROPERTY RIGHTS MCU 2008 Service Carl Zeiss PROPERTY RIGHTS The instruments, units or procedures described in this manual are protected by patents. M60-2-0019 e 05/2012...