2.6

Technical Data

Dimensions (width x depth x height)
MCU 2008 .................................................................................... approx. 250 mm x 220 mm x 100 mm
Weight
MCU 2008 ........................................................................................................................ approx. 2.5 kg
Joystick ............................................................................................................................. approx. 0.4 kg
Mechanical stage .............................................................................................................. approx. 4.0 kg
Ambient conditions
Transportation (in packaging):
Permissible ambient temperature .................................................................................... -40 to +70 °C
Storage:
Permissible ambient temperature ................................................................................... +10 to +40 °C
Permissible relative humidity (no condensation) ..................................................... max. 75 % at 35 °C
Operation:
Permissible ambient temperature ................................................................................... +10 to +40 °C
Permissible relative humidity (no condensation) ..................................................... max. 75 % at 35 °C
Atmospheric pressure ......................................................................................... 800 hPa to 1060 hPa
Altitude at installation site ............................................................................................... max. 2000 m
Pollution degree ............................................................................................................................... 2
Operating data
Intended site ....................................................................................................................... closed rooms
Protection class ...................................................................................................................................... I
Protection type ................................................................................................................................ IP 20
Electrical safety............................................................ in compliance with DIN EN 61010-1 (IEC 61010-1)
.......................................................................................... under consideration of CSA and UL directives
Overvoltage category............................................................................................................................. II
Radio interference suppression ......................................................... in accordance with EN 55011 class B
Noise immunity .................................................................................... in accordance with DIN EN 61326
Line voltage ............................................................................................................ 100 to 240 V ±10 %
............................................................................
Line frequency........................................................................................................................... 50/60 Hz
Power consumption .............................................................................................................. max. 50 VA
Fuses according to IEC 127 .......................................................................................... T 2.0 A/H / 250 V