Specification Omd-24 Fc (Conversion-Kit) - Deckma Hamburg OMD-24 Series Instruction Manual

15 ppm bilge alarm
Table of Contents

Advertisement

8.1

Specification OMD-24 FC (Conversion-Kit)

Range:
Accuracy:
Linearity:
Display:
Power Supply:
Consumption:
Alarm Points 1 + 2:
Alarm 1 Operating Delay:
(for annunciation purpose)
Alarm 2 Operating Delay:
(for control purposes)
Alarm Indication:
(Alarm 1, 2 System Fault)
Alarm Contact Rating:
(Alarm 1, 2, System Fault)
Output Signal:
Sample/ Fresh Water Pressure:
Recommended Sample Flow:
Flow Meter:
Measuring Range:
Sample Water Temperature:
Ambient Temperature:
Roll:
Size:
(Computer Unit)
(Automatic Cleaning Device)
(Measuring Cell)
Weight:
Degree of Protection:
Air Supply (optional)
Air Pressure Regulator (optional)
Pipe Connections: Air, Water
(optional)
 Technical specifications are subject to change without notification.
0 – 30 ppm, Trend indication 50 ppm
According IMO MEPC. 107(49)
0 – 30 ppm better than ± 2 %
Yellow Graphic Display
24 V AC or DC ± 10 %
Automatic Voltage selection
< 10 VA
Adjustable between 1 – 15 ppm*
(Works adjustment 15 ppm)
Adjustable between 1 – 540 sec.
(Works adjustment 2 sec.)
Adjustable between 1 – 10 sec.
(Works adjustment 10 sec.)
Red LEDs
Potential free 1 pole change over contacts,
3 A / 240 V
0 – 20 mA or 4 – 20 mA selectable, active,
ext. Load < 150 
0 – 6 bar
Approx. 2 l/min
Vortex Type: 0.50 – 4,5 l/min
Low Flow Alarm 0.7 l/min (factory set)
+ 1 to + 65° C
+ 1 to + 55° C
Up to 45°
185 mm W x 210 mm H x 65 mm D
140 mm W x 240 mm H x 120 mm D
140 mm W x 280 mm H x 120 mm D
1 Kg
IP 65
4 – 6 bar
Typical 4 bar
R ¼" Female
Page: 42