4.1

Specification OMD-24

Range:
Accuracy:
Linearity:
Display:
Power Supply:
Consumption:
Alarm Points 1 + 2:
Alarm 1 Operating Delay:
(for annunciation purpose)
Alarm 2 Operating Delay:
(for control purposes)
Alarm Indication:
(Alarm 1, 2, System Fault)
Alarm Contact Rating:
(Alarm 1, 2, System Fault)
Output Signal:
Sample/ Fresh Water pressure:
Sample Flow:
Sample Water Temperature:
Ambient Temperature:
Roll:
Size:
Computer Unit
Measuring Cell Assembly
Distance Computer Unit to
Measuring Cell:
Weight: (with Measuring Cell)
Degree of Protection:
Pipe connections:
 Technical specifications are subject to change without notification.
*By request the alarm set point can be set to 5 ppm max.
0 – 30 ppm, Trend indication 50 ppm
According IMO MEPC. 107(49)
0 – 30 ppm better than ± 2 %
Yellow Graphic Display
24 V AC or DC +/- 10%
< 5 VA
Adjustable between 1 – 15 ppm*
(Works adjustment 15 ppm)
Adjustable between 1 – 540 sec.
(Works adjustment 2 sec.)
Adjustable between 1 – 10 sec.
(Works adjustment 10 sec.)
Red LEDs
Potential free 1 pole change over contacts,
3 A / 240 V.
0 – 20 mA or 4 – 20 mA selectable,
ext. Load < 150 
0 – 10 bar recommended range of installation
Approx. 0.1 – 3 l/min
+1 to +65 °C
+1 to +55 °C
Up to 45°
185 mm W x 210 mm H x 65 mm D
140 mm W x 160 mm H x 65 mm D
Up to 0.5 m
2.5 kg
IP 65
R ¼" Female