Removing the insulation
The insulation can be removed, to facilitate handling in
confined spaces (the diameter of the water heater
without insulation is for EKS 500 Ø670 mm, for EKS 750
Ø770 and for EKS 1000 Ø870 mm).
Lift off the plastic top and the top insulation.
On EKS 500, the lifting eye on the top must be un-
screwed first.
Remove the joining plates holding the insulated jacket
halves together.
Unhook and remove the insulated jacket halves, the
outer diameter of the heater becomes approx. 200
mm less without the insulated jackets.
The figure shows EKS 1000 with
insulation.
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion, and in the hole for the lifting eye on EKS 500. Finally,
fit all the enclosed cover discs on each connection by
pressing them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.
NOTE
In certain cases, more insulation plugs are en-
closed than are required.
20
Do not use any tools when dis-
mantling the joining plate.
Insulation removed
EKS 500, 750, 1000 L | GB