Controls
In the "Controls" area, you can enable/disable the Gate or perform a reset of the reader and
thus of the error messages.
Table 8- 2
Parameter
Enable
gate
Automatic
reset
Manual
reset
Statistics
Statistics or meter readings to/from read operations and the read quality are displayed in the
"Statistics" area.
Table 8- 3
Parameter
Read results
Objects entered
Objects lost
Read
NoRead
NoRead
(fast trigger)
Triggered while
reading
SIMATIC Ident CB Gate
Operating Instructions, 08/2022, C79000-G8976-C671-01
Description of the "Controls" parameters
Description
Buttons for enabling/disabling the CB Gate.
Switch to enable/disable the automatic acknowledgment function of
error messages.
When the function is enabled, the reader and all error messages are
automatically reset by the "WRITE-CONFIG" command as soon as error
messages occur.
Button for manual reset of all error messages.
When the function is enabled, the reader and all error messages are
automatically reset by the "WRITE-CONFIG" command.
Note that critical error messages (e.g. cable break) need to be resolved
first before you can reset them with this button.
Description of the "Statistics" parameters
Description
Number of objects that have previously triggered read operations
(Trigger).
Number of objects that entered the read window but did not trigger a
read operation (Trigger).
This is an error counter that is counted up when an object has
completely crossed the read window without being read because the
previous object is still being processed.
Note: To avoid this error, the distance between two objects is increased
or the speed of the conveyor system is reduced.
Number of successful read operations (object detected)
Number of unsuccessful read operations
This is an error counter that is counted up when an object has not been
identified or when multiple objects that could not be clearly identified
were found in the antenna field.
Number of unsuccessful read operations
This is an error counter that is counted up if the read operation (Trigger)
was set too late so that the object could not be read because processing
of the previous object was not finished in time.
Number of read operations started late
This is an error counter that is counted up when the time interval
between two objects is too small so that the detected transponder could
not be clearly assigned to an object.
Note: To avoid this error, the distance between two objects is increased
or the speed of the conveyor system is reduced.
Operation via the CB Gate user interface
8.2 Menu items
45