4.3.1 Connection of compressed air

The compressed air connection must supply 6 bar.
1.
Establish the compressed air connection (1) between the grid
and the compressed-air maintenance unit.
2.
Check the pressure at the compressed-air maintenance unit (2)
and adjust to 6 bar.
3.
Check that the scale (3) of the compressed-air maintenance unit
is at the value 1.
The compressed air can be enriched with standard pneumatic oil
through the oiler of the maintenance unit.
ATTENTION!
Damage to the machine
Contaminated compressed air may cause damage to the ma-
chine.
Only use clean, and water-free compressed air.