16Kw 1-Phase Units - EAS Electric M-THERMAL 2 BIBLOCK Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

9.3 4~16kW 1-phase units

1) PCB A
4-10kw Inverter module
Remarks: for 4-6kw, two capacitors
9
8
Coding
Assembly unit
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Output port for +12V/9V(CN20)
5
Port for fan(CN19)
2) PCB A 12-16kw
CN502
10
9
Coding
Assembly unit
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Port for fan(CN19)
5
Output port for +12V/9V(CN20)
Coding
6
7
8
9
/
Inverter module
CN501
Coding
10
1
2
3
CN20
7
6
Assembly unit
Reserved(CN302)
Port for communication with PCB B(CN32)
Input port N for rectifier bridge(CN502)
Input port L for rectifier bridge(CN501)
/
1
2
3
4
CN19
CN6
8
Assembly unit
6
Port for communication with PCB B(CN32)
7
Port for high pressure switch (CN23)
8
Reserved(CN6)
9
Input port L for rectifier bridge(CN501)
Input port N for rectifier bridge(CN502)
20
4
5
CN20
5
CN32
6
7
CN23
V.2

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Eth10vaEth12vaEth12va-triEth16vaEth16va-tri

Table of Contents