Service Air Piping - Sullair LS-25S Operator's Manual And Parts List

Industrial rotary screw air compressor
Table of Contents

Advertisement

Figure 4 ---1 Service Air Piping (Typical Installation)
DO NOT install a water---cooled or an air---cooled/
aftercooled compressor without adequate freeze
protection where it will be exposed to temperature
less than 32_F(0_C).

4.3 SERVICE AIR PIPING

Service air piping should be installed as shown in
F i g u r e 4 --- 1
. A s h u t --- o f f v a l v e s h o u l d b e i n s t a l l e d t o
isolate a compressor from the service line if re-
quired. Also notice that the service line should be
equipped with water legs and condensate drains
throughout the system.
Section 4
INSTALLATION
BLOCK AND
BYPASS VALVES
WA R N I N G
!
"The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping." (I)
Sullube 32 should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints. Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents