Thermal Valve Maintenance; Drive Coupling Installation And Maintenance - Sullair LS-25S Operator's Manual And Parts List

Industrial rotary screw air compressor
Table of Contents

Advertisement

to
Figur e 6 --- 1 1
for the l oc a tion) . When the j am nut
is loose, turn the adjusting screw clockwise to in-
crease or counterclockwise to decrease the set-
ting.
Above 100 psig (6.9 bar), the spiral valve regulator
should allow pressure to flow into the chamber of
the spiral valve actuator. The spiral valve should
start to rotate at this time.
At approximately 108 psig (7.4 bar), the Sullicon
regulator should allow pressure to flow into the
control chamber of the Sullicon Control. The Sul-
licon Control level should start to move at this time.
Cycle the Control System several times and re-
check all pressure settings.

THERMAL VALVE MAINTENANCE

Refer to
Figur e 6 --- 5
. For ther mal val v e mainte -
nance, use repair kit number 001084 for standard
compressors and number 001149 for 24KT com-
pressors and follow the procedure explained below
for installation.
1. Remove appropriate piping for disassembly of
the thermal housing.
2. Remove the four (4) capscrews which hold the
housing together and pull the upper housing
away from the lower housing.
3. Remove element.
4. Remove and replace the element seal in the up-
per housing.
Figure 6 ---6 Drive Coupling
Section 6
MAINTENANCE
Figure 6 ---7 Drive Coupling Alignment
5. Remove and replace the o---rings between the
upper and lower housings.
6. Replace element.
7. Reassemble the housing.
DRIVE COUPLING INSTALLATION AND MAIN-
TENANCE
R e f e r t o
F i g u r e s 6 --- 6
,
6 --- 7
installation and alignment, the tools required are a
straight edge, a measuring scale, one set of feeler
gauges, a set of standard Allen wrenches and one
set of standard socket wrenches.
WA R N I N G
!
Disconnect all power at source before attempting
maintenance or adjustments.
For installation and maintenance of the drive cou-
pling, follow the steps explained below.
STEP 1 MOUNT HUBS --- Mount the motor hub
and the compressor hub onto the respective shaft.
Position the hubs to establish the correct gap
specified in Table 1. Secure each hub with a
setscrew.
STEP 2 OFFSET ALIGNMENT --- Clean any fluid,
grease, dirt or paint from coupling hubs. Rotate
shafts so that a straight edge will rest squarely (or
within the maximum limit shown in Table 1) on both
flanges and at a point 90_ away. The vertical offset
alignment is adjusted by the addition or removal of
motor mounting shims. Loosen the motor mount-
ing bolts and slide the motor sideways to correct
the horizontal offset.
STEP 3 COUPLING GAP AND ANGULAR ALIGN-
MENT --- Position the hubs to establish the proper
a n d
6 --- 8
. F o r c o u p l i n g
31

Hide quick links:

Advertisement

Table of Contents
loading