Sullair DE-18 Series Operator's Manual And Parts List page 48

Oil-free air compressor 1500 cfm
Hide thumbs Also See for DE-18 Series:
Table of Contents

Advertisement

Section 8
TROUBLESHOOTING
8.5 C267 INPUTS/OUTPUTS
267
267 PIN
PIN
CAPABILITY
J1-1
OUTPUT #7
J1-2
OUTPUT #5
J1-3
OUTPUT #3
J1-4
OUTPUT #1
J1-5
POWER 2
J1-6
OUTPUT #8
J1-7
OUTPUT #6
J1-8
OUTPUT #4
J1-9
OUTPUT #2
J1-10
POWER 2
J2-1
ANALOG 6
J2-2
ANALOG 4
J2-3
ANALOG 2
J2-4
INPUT 8
J2-5
INPUT 6
J2-6
INPUT 4
J2-7
INPUT 2
J2-8
FREQUENCY INPUT
J2-9
POWER GROUND
J2-10
ANALOG 7
J2-11
ANALOG 5
J2-12
ANALOG 3
J2-13
ANALOG 1
J2-14
INPUT 7
J2-15
INPUT 5
J2-16
INPUT 3
J2-17
INPUT 1
J2-18
POWER 1
42
INPUT
SIGNAL TYPE
USE
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
POWER
POWER
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
DIGITAL
TRANSISTOR
POWER
POWER
ANALOG
4-20 mA
ANALOG
4-20 mA
ANALOG
4-20 mA
DIGITAL
SWITCH
DIGITAL
SWITCH
DIGITAL
SWITCH
DIGITAL
SWITCH
FREQUENCY
ANALOG
0-5 VDC
ANALOG
0-5 DC
ANALOG
4-20 mA
ANALOG
4-20 mA
DIGITAL
SWITCH
DIGITAL
SWITCH
DIGITAL
SWITCH
DIGITAL
SWITCH
DESCRIPTION
NOT USED
COMPRESSOR FAULT
LIGHT
COMPRESSOR ALARM
LIGHT
OIL MAKE-UP SOLENOID
SPARE
SPARE
AIR INTAKE VALVE
SOLENOID
DRAIN #1
OIL FILTER OUT
TEMPERATURE T3
2ND STAGE DISCHARGE
TEMPERATURE T2
1ST STAGE DISCHARGE
TEMPERATURE T1
NOT USED
NOT USED
SPARE
CADP1 COMPRESSOR AIR
DIFFERENTIAL PRESSURE
SWITCH #1
NOT USED
NOT USED
NOT USED
T5 DISCHARGE
TEMPERATURE
T4 2ND STAGE INLET
TEMPERATURE
NOT USED
CAT ECM SERVICE
REQUIRED
CAT ECM DIAGNOSTIC
CAT ECM WARNING

Advertisement

Table of Contents
loading

Table of Contents