Interfaces / Communication
USB interface
Digital inputs / outputs
LAN interface
WAN interface
SIM card reader
(mini SIM)
SMA socket
RP-SMA socket
GSM module 3G (UMTS)
GSM module 4G (LTE)
Wi-Fi modem
Failover WAN > Modem / Wi-Fi
Interface specification
LAN interface
WAN interface
USB interface
2 pieces I/Os
Digital input
Digital output
VPN
Can only be operated with (my)mbCONNECT24 *.
VPN protocol
Encryption parameter
Authorization
* The types MDH 866 and MDH 867 can only be operated in the portal (my)mbCONNECT24 V2.
Network /Security
Firewall
IP router
Service
Time synchronization
Page 128 von 131 | Version: 2.2.1 - EN | Mar 28
MDH 860
MDH 862
EU / AT&T
1 x
2 x
3 x
1 x
10/100 Mbit/s full and half duplex operation, autodetection patch cable / crossover cable
10/100 Mbit/s full and half duplex operation, autodetection patch cable / crossover cable
USB Host 2.0
These connectors can be independently configured as a digital input or digital output -
only in the mbCONNECT24 V2 portal.
10 – 30 V DC (low 0 – 3.2 V DC, high 8 – 30 V DC)
10 – 30 V DC to a maximum of 0.5 A per output
OpenVPN, 1 tunnel
Control Channel: TLSv1.2, cipher ECDHE-RSA-AES256-GCM-SHA384
Data Channel:
Cipher 'AES-256-GCM' initialized with 256 bit key
Pre-Shared-Key, X.509
1:1 NAT, IP-Filter, Port-Forwarding, stateful inspektion
NAT-IP, TCP/IP routing, IP forwarding
DHCP client, NTP client
NTP server
th
, 2022 |
Type
MDH 863
1 x
1 x
2 x
2 x
4 x
4 x
1 x
2 x
1 x
1 x
1 x
MDH 866
MDH 867
EU / AT&T
1 x
1 x
2 x
2 x
3 x
3 x
1 x
1 x
1 x
2 x
1 x
1 x
1 x