13. LR1110 Provisioning
13.1 Description
The LR1110 is pre-provisioned during the production test flow with default DeviceEUI and JoinEUI unique identifiers, as
defined per the LoRaWAN
https://lora-alliance.org/
It also pre-provisioned with a DevicePIN allowing the device registration to LoRa Cloud™ Join services. For more
information, please refer to the LoRa Cloud™ website: https://www.loracloud.com/portal/join_service
All those unique identifiers are stored in the device persistent memory. They are pre-configured by Semtech to ease the
LoRaWAN
implementation and access to LoRa Cloud™ Join services, but can be ignored by the user.
®
13.2 Provisioning Commands
13.2.1 GetDevEUI
The command GetDevEUI( ) allows reading back the LR1110 LoRaWAN
device.
Table 13-1: GetDevEUI Command
Byte
Data from Host
Data to Host
Table 13-2: GetDevEUI Response
Byte
0
Data from
0x00
Host
Data to
Stat1
Host
•
DevEUI is coded on 8 Bytes, in little endian.
13.2.2 GetAppEUI
The command GetAppEUI( ) allows reading back the LR1110 LoRaWAN
device.
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
standard. For more information, please refer to the LoRa Alliance
®
0
1
0x01
0x25
Stat1
Stat2
1
...
0x00
...
DevEUI
DevEUI
...
(63:56)
www.semtech.com
DevEUI unique Identifier pre-provisioned in the
®
8
0x00
(7:0)
AppEUI unique Identifier pre-provisioned in the
®
website:
®
115 of 130
Semtech