- 9 dBm (0xF7) to +22 dBm(0x16) by step of 1 dB if the High Power PA is selected
For TxPower > +15 dBm, the user must select the VBAT supply for the PA using the SetPaConfig command.
RampTime defines the PA power ramping time. The Ramp Time can be set from 10 us to 3400 us according to the
following table:

Table 9-6: RampTime

RampTime
SET_RAMP_10U
SET_RAMP_20U
SET_RAMP_40U
SET_RAMP_80U
SET_RAMP_200U
SET_RAMP_800U
SET_RAMP_1700U
SET_RAMP_3400U
A value of Ramp Time value of 40 us allows the best trade-off between a fast RF power establishment and the minimum RF
spurious, therefore a compliance to the radio standards.
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
Value
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
www.semtech.com
Ramp Time in us
10
20
40
80
200
800
1700
3400