Setpacketparam; Table 8-7: Coding Rate; Table 8-8: Lowdatarateoptimize; Table 8-9: Setpacketparam Command - Semtech LR1110 User Manual

Hide thumbs Also See for LR1110:
Table of Contents

Advertisement

CR configures the Coding Rate

Table 8-7: Coding Rate

CR
0x01
0x02
0x03
0x04
0x05
0x06
0x07
LowDataRateOptimize reduces the number of bits per symbol:

Table 8-8: LowDataRateOptimize

LowDataRateOptimize

8.3.2 SetPacketParam

The command SetPacketParam( ) configures the parameters of the RF packet for the selected modem. Since the parameters
are modem dependent, the description hereafter is valid only for the LoRa® modem.

Table 8-9: SetPacketParam Command

Byte
0
Data from Host
0x02
Data to Host
Stat1
PbLengthTX defines the length of the LoRa® packet preamble.
Coded on 2 Bytes, from 0x0001 (1) to 0xFFFF (65535). Minimum of 12 with SF5 and SF6, and of 8 for other SF
advised.
HeaderType defines if the header is explicit or implicit:
0x00= explicit header (default)
0x01= implicit header
PayloadLen defines the size of the payload (in Bytes) to transmit or the maximum size of the payload that the receiver
can accept.
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
Short Interleaver CR= 4/5
Short Interleaver CR= 4/6
Short Interleaver CR= 4/7
Short Interleaver CR= 4/8
Long Interleaver CR= 4/5
Long Interleaver CR= 4/6
Long Interleaver CR= 4/8
0x00
0x01
1
2
0x10
PbLengthTX
(15:8)
IrqStatus
Stat2
(31:24)
www.semtech.com
Description
LowDataRateOptimize off
LowDataRateOptimize on
3
4
PbLengthTX
HeaderType
(7:0)
IrqStatus
IrqStatus
(23:16)
(15:8)
Overhead Ratio
1.25
1.5
1.75
2
1.25
1.5
2
Description
5
6
PayloadLen
CRC
IrqStatus
0x00
(7:0)
7
InvertIQ
0x00
56 of 130
Semtech

Advertisement

Table of Contents
loading

Table of Contents