Table 5-3: GetVbat Command
Byte
Data from Host
Data to Host
Table 5-4: GetVbat Response
Byte
Data from Host
Data to Host
5.4 Power-On-Reset and Brown-Out-Reset
The LR1110 features both POR and BRN features.
The POR/BRN ensure a proper startup of the circuit maintaining the internal blocks reset until a safe level of the battery
voltage is reached, for example at battery insertion. The BRN triggers a device reset in case the battery voltage goes below
the safe operation threshold of 1.7V (typically). The POR/BRN detector has a 50 mV hysteresis.
Refer to
Figure 5-1: LR1110 POR and BRN Functions
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
0
0x01
Stat1
0
0x00
Stat1
5 VBat(7:0)
-------------------------------- -
=
VBAT V
255
for an illustration of the POR and BRN functions.
www.semtech.com
Vbat(7:0)
1.35
–
1
1
0x19
Stat2
1
0x00
36 of 130
Semtech