5.5 Low Battery Detector

The Low Battery Detector (LBD) detects when the supply voltage VBAT drops below 1.88 V (typ). The LBD indication is given
through an interrupt signal, hence minimizing the host activity in critical supply voltage conditions. The LBD IRQ shall be
activated though the command SetDioIrqParams().