14.2 Commands

14.2.1 SetTxCw

The command SetTxCw ( ) sets the device in TX continuous wave mode (unmodulated carrier).

Table 14-2: SetTxCw Command

Byte
Data from Host
Data to Host
This command immediately sets the device in TX CW mode. Therefore, the operating frequency and the PA configuration
commands (including the RF output power) have to be called prior to this command.

14.2.2 SetTxInfinitePreamble

The command SetTxInfinitePreamble( ) transmits an infinite preamble sequence.

Table 14-3: SetTxInfinitePreamble Command

Byte
Data from Host
Data to Host
This command immediately starts transmission of the infinite preamble sequence. Therefore, the operating frequency and
the PA configuration commands (including the RF output power) have to be called prior to this command.
LR1110