14.2 Commands
14.2.1 SetTxCw
The command SetTxCw ( ) sets the device in TX continuous wave mode (unmodulated carrier).
Table 14-2: SetTxCw Command
Byte
Data from Host
Data to Host
This command immediately sets the device in TX CW mode. Therefore, the operating frequency and the PA configuration
commands (including the RF output power) have to be called prior to this command.
14.2.2 SetTxInfinitePreamble
The command SetTxInfinitePreamble( ) transmits an infinite preamble sequence.
Table 14-3: SetTxInfinitePreamble Command
Byte
Data from Host
Data to Host
This command immediately starts transmission of the infinite preamble sequence. Therefore, the operating frequency and
the PA configuration commands (including the RF output power) have to be called prior to this command.
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
0
0x02
Stat1
0
0x02
Stat1
www.semtech.com
1
0x19
Stat2
1
0x1A
Stat2
118 of 130