0x01: stop on Preamble detection

7.2.8 GetRssiInst

The command GetRssiInst( ) returns the instantaneous RSSI value at the precise time when the command is sent. Therefore
if no RF packet is present, the RSSI value returned by the command GetRssiInst( ) will correspond to the RF noise.

Table 7-8: GetRssiInst Command

Byte
Data from Host
Data to Host

Table 7-9: GetRssiInst Response

Byte
Data from Host
Data to Host
The RSSI in dBm is calculated using the following formula:
RSSI (dBm)= -Rssi/2

7.2.9 GetStats

The command GetStats( ) returns the internal statistics of the received RF packets:

Table 7-10: GetStats Command

Byte
Data from Host
Data to Host

Table 7-11: GetStats Response

Byte
Data from Host
0x00
Data to Host
Stat1
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
0
1
0x02
0x05
Stat1
Stat2
0
1
0x00
0x00
Stat1
Rssi
0
1
0x02
0x01
Stat1
Stat2
0
1
2
0x00
0x00
NbPkt
NbPkt
Received
Received
(15:8)
(7:0)
www.semtech.com
3
4
0x00
0x00
0x00
NbPkt
NbPkt
Data1
CrcError
CrcError
(15:8)
(15:8)
(7:0)
5
6
7
0x00
0x00
Data1
Data2
(7:0)
(15:8)
8
0x00
Data2
(7:0)