NbPktReceived is the total number of received packets.
•
NbPkCrcError is the total number of received packets with a CRC error.
•
Data1 is PacketType dependant:
(G)FSK mode: Data1= NbPacketLengthError(15:0): number of packet with a length error
LoRa® mode: Data1=NbPktHeaderErr(15:0): number of packets with a Header error
•
Data2 is PacketType dependant:
(G)FSK mode: Data2=0x00
LoRa® mode: Data2=NbPktFalseSync(15:0): number of false synchronizations.
Statistics are reset on a Power On Reset, power down, or by the command ResetStats( ).
7.2.10 ResetStats
The command ResetStats( ) resets the internal statistics of the received RF packets:
Table 7-12: ResetStats Command
Byte
Data from Host
Data to Host
7.2.11 GetRxBufferStatus
The command GetRxBufferStatus( ) returns the length of the last RF packet received and the offset in the RX buffer of the
first byte received:
Table 7-13: GetRxBufferStatus Command
Byte
Data from Host
Data to Host
Table 7-14: GetRxBufferStatus Response
Byte
Data from Host
Data to Host
•
PayloadLengthRX is the Palyoad length of the last RF packet received.
RxStartBufferPointer is the offset in the RX buffer of the first byte received.
LR1110
User Manual
Rev.1.0
UM.LR1110.W.APP
March 2020
0
0x02
Stat1
0
0x02
Stat1
0
0x00
Stat1
PayloadLengthRX
www.semtech.com
1
0x00
Stat2
1
0x03
Stat2
1
0x00
RxStartBufferPointer
2
0x00
48 of 130