Download Print this page

Daikin CTKC15QVM4 Removal Procedure page 15

1.5/2.0/2.5/3.5/4.2/5.0 kw class, 9000/12000/15000/18000 btu/h class

Advertisement

Si041551EB
Step
2. Remove the swing motor
for horizontal blade.
1
Remove the filament
tape.
2
Remove the screw, and
then the swing motor
for horizontal blade.
3. Remove the swing motor
for vertical blades.
1
Remove the 2 screws.
2
Release the shaft of the
vertical blade ASSY
from the swing motor
shaft with a flat
screwdriver and
remove the swing motor
ASSY.
Removal Procedure
Procedure
Hook
Bottom view
Shaft
Drain Pan / Swing Motors / Vertical Blade ASSYs
Hook
(R22085)
Filament tape
Swing motor for
horizontal blade
(R22086)
(R24353)
Swing motor ASSY
(R22088)
Points
When reassembling, make
sure that all the 4 hooks are
fastened.
Some models do not have
the swing motor for vertical
blades.