Step
5. Remove the vertical blade
ASSYs (manual swing
models).
1
Unfasten the upper 2
hooks.
2
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
3
Remove the vertical
blade ASSY.
4
Remove the other
vertical blade ASSY in
the same way.
Removal Procedure
Procedure
Hook
Vertical blade ASSY
Hook
Drain Pan / Swing Motors / Vertical Blade ASSYs
Each vertical blade ASSY
has 5 fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.