Parameter
"Return Gradi-
ent 1 Alternat-
ive Threshold"
54
Range of val-
Description
ues
0 ‑ 100 [W%]
Threshold value from
which "Return Gradient 1"
or "Return Gradient 1 Al-
ternative" is applied.
Example:
If the difference between
the rated power and the
currently reduced power is
less than or equal to the
threshold value, "Return
Gradient 1" is applied. If
the difference between
the rated power and the
current reduced power is
greater than or equal to
the threshold, "Return
Gradient 1 Alternative" is
applied. 0.01 - 100 %.
100 % means that "Return
Gradient 1" is always ap-
plied.
Availability