Air Configuration; Operating Instruction - Ebyte E104-BT02 User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.

5.12 Air configuration

The module supports the air configuration function. After the Bluetooth connection is established in the slave state, the host can
access the "BLE DATA CONFIG" feature value under the transparent transmission service (FFF0). The configuration steps are as
follows:
1)、In the air configuration login authentication, send the command <PWDXXXXXX>, where XXXXXX is the login password,
the default is 123456, and return <OK> after success.
2)、The parameter configuration is executed, and the command is consistent with the serial port configuration command.
3)、Disconnect the Bluetooth connection.
Description:
1)、After the <PWDXXXXXX> command fails, the current login status will be exited immediately. That is, the configuration
operation needs to be resumed after the login is successful.。
2)、After the <RESTORE> command is executed, the login password is restored to the default settings.

6 Operating Instruction

Warning: Make sure the module is in wake-up mode and enters configuration mode before sending operating instruction or it is
unable to receive any configuration instruction.
Description:
1、Instruction format: the format for all operation instruction uses prefix sign '<'and suffix sign '>',
<instruction>
For example, for transmitting and receiving baud rate of serial port the format is <COMBAUD>
2、Instruction returning
Returning value
INVALID_ERR
HT_ERR
LEN_ERR
OK
3、Factory parameter setting
Others
Transparent Transmission
service
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
Unrecognized instruction or lack of prefix/suffix sign of instruction
Parameter length out of range
Baud rate
Calibration
Stop bit
Air configuration password
Serial wakeup
Data output indication
Bluetooth packet length
Bluetooth binding
UUID
Transparent Transmission UUID
BLE DATA BUFF UUID
CENTER UUID BUFF
Description
Unrecognized instruction
Correct execution
E104-BT02 User Manual
instruction format is
19200bps
NONE
1
123456
Shut Down
Open
20
Shut Down
16 bits
0xFFF0
0xFFF1
0xFFF2
8

Advertisement

Table of Contents