Module Reset Instruction; Restore Factory Mode; Configuration Instruction For Baud Rate Of Serial Port - Ebyte E104-BT02 User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Slave
Master

6.1 Module reset instruction

Instruction
<RESET>

6.2 Restore factory mode

Instruction
<RESTORE>

6.3 Configuration instruction for baud rate of serial port

Instruction
<BAUDxxx>
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
BLE DATA CONFIG
Broadcast function
Module name
Broadcasting gap
Min connecting gap
Max connecting gap
Connecting timeout
General broadcasting data
Ibeacon broadcasting data
Eddystone broadcasting data
Manufacturer name
Serial number (SN)
SYSTEM ID
Scanning gap
Scanning time
Min connecting gap
Restart BLE protocol stack (different from pin reset, it only resets protocol stack
and buffered data will be remained)
No returning
All parameters are restored to factory settings.
When succeed return to<OK>
To configure baud rate assigned by xxx (ASCII code) and optional baud rate includes 4800,
9600, 19200, 38400, 57600, 115200, 256000
E104-BT02 User Manual
0xFFF3
Open
E104-BT02
1s
10ms
10ms
5s
02 01 06
03 03 58 69
05 FF 01 02 03 05
02 01 06
1A FF 4C 00 02 15 52 41 44 49 55 00 4E 45 54 57
4F 52 4B 53 43 4F 00 01 00 02 D2
02 01 06
03 03 AA FE
0C 16 AA FE
00 63 64 65 62 79 74 65 07
CDEBYTE
160705000004
Same as MAC address
12.5ms
10ms
10ms
Description
Description
Description
9

Advertisement

Table of Contents
loading

Table of Contents