6.29 Set broadcasting gap

Instruction
<ADVGAPxxx>

6.30 Read broadcasting gap

Instruction
<AGAP>

6.31 Set max connecting gap

Instruction
<CONMAXxxx>
Special note: The max connecting gap must be larger than or equal to the min connecting gap.

6.32 Read max connecting gap

Instruction
<MAXCGAP>

6.33 Set min connecting gap

Instruction
<CONMINxxx>
Special note: The min connecting gap must be less than or equal to the max connecting gap.
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
Set broadcasting gap assigned by xxx (ASCII code) ranging from 32 to 16000, i.e., from
If parameter is out of range return to <RANGE_ERR>, when succeed return to <OK>.
Read broadcasting gap configuration,ranging from 6 to 3200, i.e., from 7ms to 4s
For example, if the gap is 1s, return to<A1600>.
Set max connecting gap assigned by xxx (ASCII code) ranging from 6 to 3200, i.e., from
If parameter is out of range return to <RANGE_ERR>, when succeed return to <OK>.
For example, if the gap is 10ms return to <CX8>.
Set min connecting gap assigned by xxx (ASCII code) ranging from 6 to 3200, i.e.,
If parameter is out of range return to <RANGE_ERR>, when succeed return to <OK>.
Description
20ms to 10s correspondingly.
Description
correspondingly.
Description
7.5ms to 4s correspondingly.
Description
Read max connecting gap
Description
from 7.5ms to 4s correspondingly.