1.1 Brief Introduction E104-BT10-IPX is a Bluetooth mesh network module designed and manufactured by Ebyte Electronic Technology Co., Ltd., which conforms to the sig mesh V1.0 standard. The single network can accommodate up to 10922 node devices. The device automatically remembers network information after entering the network.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 2、 Specification and Parameter 2.1 Limit parameter Performance Main Parameter Note Voltage over 3.6V will cause permanent damage Voltage supply [V] to module Chances of burn is slim when modules are used in...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual Antenna 50Ω Impedance Dimension and Pin Definition Pin item Pin direction Application Ground, connecting to power source reference ground PWM output Corresponds to green indicator of SIGMESH HSL PWM output Corresponds to red indicator of SIGMESH HSL...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual The best advantage of this module is that it can repeater any data in the network. Any module works as a repeater. When as a repeater, it can receive data at the same time. The coverage of the module data signal is about 50 meters. The following figure is a function diagram of repeater for user’s reference.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 4.1.1 Network Key(NetKey) Network keys are used to protect network layer communications. It is a key generated using a random number generator that meets the requirements of the core specification.(see details from Mesh Profile3.86)...
(the data compression package includes the APP related SDK for the customer to develop). A single device supports only one role. In EBYTE solution, our module supports two roles: the provisioning node and the mesh node. The provisioning node is the device responsible for networking. The mesh node is the repeater node that sends and receives data and forwards data.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual Generic Level Server 1002 Generic Default Transition Time Server 1004 Generic Power OnOff Server 1006 Generic Power OnOff Setup Server 1007 Light Lightness Server 1300 Light Lightness Setup Server 1301 Light HSL Server...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual values cannot be the same between different networks, because E104_BT10G will assign netkey to E104_BT10N and bind APPkey when networking. Networking process steps and results The formation of the entire network is completely automatic. The user only needs to give the "Add Node to Network"...
Any remaining data will be considered invalid and the module will not respond. The parameter configuration is used for parameter configuration of the current module, the SIG message is a standard mesh control message defined by sig, and the transparent transmission message is defined by Ebyte. Length(1byte HEX)...
Page 15
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 0xFD Invalid command 0xFC Networking device not scanned 0xFB Parameter obtain failure 0xFA Assign netkey failure 0xF9 Bind Appkey overtime 0xF8 Bind Appkey failure 0XF7 Last networking not finished 1. NetKey configuration Key is for network ID assigned by provisioner,format is as follows...
Page 16
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 1、Suitable for E104-BT10G-IPX 2、After configuration, the system will restart once 4. To read AppKey Operation Parameter code Request 0x03 Read 16 bytes of AppKey data Respond 0x03 Return configured 16 bytes of AppKey data :02 C0 03...
Page 17
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 7.Networking filter configuration Operation Parameter code Request 0x06 Serial number +MAC address of allowed device Respond 0x06 MAC address of allowed device Request:09 C0 06 00 112233445566 Respond:33 40 06 01 112233445566 00…00(00...00 means space for example unbound MAC)...
Page 18
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual code Request 0x09 Respond Return MAC of networking device and assigned unicast 0x09 address and element numbers Request:02 C0 09 example Respond:0B 40 09 112233445566 0004 03 Notes: 1、Suitable for E104-BT10G-IPX 2、Return MAC of networking device and assigned unicast address and element...
Page 19
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 02:115200 03:76800 04:57600 05:19200 06:9600 07:4800 Notes: 1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX 13.Power configuration Operation code Parameter Request 0x12 Power number to be configured(range:0x00~0x0A) Respond 0x12 Return configured power number Command...
Page 20
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 04:-10dBm 05:-14dBm 06:-20dBm 07:-24dBm 08:-28dBm 09:-30dBm 0A:-37bBm Notes: 1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX 15.To read MAC Operation Parameter code Request 0x11 Respond 0x11 Return current MAC address of device Request:02 C0 01 example Respond:08 40 F0 112233445566...
Page 21
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX 2、Status value 00 means succeed 18. To obtain software version number Operation Parameter code Request 0x16 Respond 0x16 software version number Request:02 C0 16 example Respond:04 40 16 10 00 Notes:...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 21. Query whether enter sleep and timeout for entering sleep Operation Parameter code Request 0x18 Respond Query whether E104-BT10N-IPX enter sleep and timeout 0x18 for entering sleep Request:02 c0 18 For example Respond:03 40 18 05...
0004 0001 00112233445566778899 5、Quick start This chapter introduces how E104-BT10-IPX forms network , and how to control transmitting and receiving of network message. 5.1 Restore factory setting Send the following command 02 C0 15 (Restore factory setting) Then there are a return, 03 43 15 00 (sometimes the value returned after restarting or restoring the factory may be one more byte, ignore it.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 5.2 Enter network E104-BT10G-IPX test board and E104-BT10N-IPX are respectively plugged into the computer USB interface (PC needs to install USB serial drive, see the data compression package), open the serial debugging assistant to select the baud rate 115200bps, 8 data bits, no parity, 1 stop bit, select hexadecimal transmission.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 5.4Transparent transmission 5.4.1 Broadcast transmission Device 0001 broadcasts “ ” in hex format 11223344AA See 3.3,input target address as FFFF ,all device in the network can receive data Transmitting 08 c2 FFFF 11223344AA...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 5.5 Low power Entering the sleep mode (refer to 4.3.1.20-4.3.1.21) requires configuration parameter instructions. It can be awakened by setting the 24 pin low, or it can be awakened by sending any data through the serial port (wake data will be discarded).
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10-IPX User Manual 8、Series product Frequency TX power Distance Size Model Package Interface E104-BT10 TLSR8269F512 2.4G 19*13 Revision history Version Date Description Operator 2019-4-12 Initial Version 2019-11-11 Function update About us Website: www.ebyte.com Sales: info@cdebyte.com...