Wake-Up Mode; Configuration Mode; Data Validity; Role Selection - Ebyte E104-BT02 User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
2) When masters and slaves enter this mode, its scanning and broadcasting function remain unaffected.

5.2 Wake-up mode

In any case, WKP (P06) or serial RX pin (selectable command <COMWKPON> configuration to enable serial port wake-up)
input falling edge, the module wakes up from low power mode, if the command <WSMON> turns on mode feedback, wake up The
serial port will automatically output WAKEUP to notify the user that the wake-up operation is successful. From the detection of the
falling edge to the completion of the module wake-up for about 7 ms, the transparent transmission function is temporarily disabled
until the system wakes up successfully and the system returns to normal.

5.3 Configuration mode

In wake-up mode, the module enters configuration mode via pulling down Pin P00 and now any data received by the module is
regarded as configuration instructions rather than for transparent data transmission, that is, the transparent transmission function is
invalid.
Description:
1) Any data transmitted by the master via Bluetooth channel "CENTER DATA BUFF" is not for transparent transmission if
Bluetooth is connected now, and channel "BLE DATA BUFF" will receive feedback information "<CONFIG MODE BUSY>"to
indicate that the slave is in configuration mode and doesn't receive data via transparent transmission.
2) In configuration mode, all configured information for the module will be saved after powering down and it will operate
according to the new configuration when powering up next time.

5.4 Data validity

Bluetooth outputs transparent transmission via serial port when receiving data. To ensure correct receiving of external MCU, at
10 ms before UART outputs the first start bit, P03 (APP) pulls down and wakes up external MCU till data transmission is completed
and P03 recovers a high level.. As shown in the figure:
Description: 1) The data output valid function can be commanded to turn on or off with <APPON>/<APPOFF>.

5.5 Role selection

The module can be configured as a master or a slave. In 160ms after powering up it starts to read the level signal of Pin P14. If a
low level signal is detected the module will be configured as the master; if a high level signal is detected it will be the slave; if the pin
floats, module with internal pull-up resistance will act as a slave. Role configuration is only valid when the module is powered up and
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT02 User Manual
5

Advertisement

Table of Contents
loading

Table of Contents