Startup Activities Of The Tim Module; Startup Of The Tim 3V-Ie Variants - Siemens SIMATIC NET SINAUT ST7 System Manual

Station control system
Table of Contents

Advertisement

5.7

Startup activities of the TIM module

5.7.1

Startup of the TIM 3V-IE variants

Introduction
During startup, the LEDs on the front panel of the TIM 3V-IE variants have a different
significance than during normal operation. They are optical indicators of the various startup
phases and provide detailed information about any errors detected during startup. The only
exceptions are the LINK and RX/TX LEDs that have no significance during the startup of the
TIM 3V-IE variants.
LED displays during startup
The following table summarizes the startup phases.
Table 5-44
LED activity on the TIM 3V-IE variants during the various startup phases
Phase
Activity
1
Power ON
followed by hardware initialization
2
Loading the operating system from flash
memory
3
Starting VxWorks operating system
4
Loading and starting TIM firmware
5
Initializing flash file system and starting
the start manager
6
Loading and starting P bus driver
7
Loading and starting subscriber
management (SubA)
8
Loading and starting LAN-COM
9
Loading and starting subscriber
management (MesA)
10
Loading and starting time-of-day driver
11
Loading and starting the TD7 software of
the TIM (TD7onTIM) on the TIM
12
Loading and starting WAN driver
13a
Startup completed without error
13b
Startup completed with error
13c
Startup aborted - user parameter
assignment missing Module expects user
parameter assignment
13d
Startup aborted -
No firmware loaded.
13e
Startup aborted - No SDBs and no
firmware loaded.
13f
Default startup completed
1) The LEDs KBus, TxD and RxD now operate in normal mode
2) The LEDs KBus, TxD and RxD remain in the phase in which the error occurred
SINAUT ST7 Station control system - System Manual
System Manual, 05/2007, C79000-G8976-C178-06
Installing and putting a TIM into operation
5.7 Startup activities of the TIM module
SF
RUN
STOP
On
On
On
Off
On
On
Off
Off
On
Off
Off
Off
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
Flashes
On
Off
On
Off
On
Off
On
Off
Off
On
Off
Off
On
Off
Off
On
Off
Flashes
Flashes
KBus
TxD
RxD
On
On
On
On
On
On
On
On
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
X
X
1)
1)
X
X
2)
2)
Flashes
Flashes
On
Flashes
Flashes
Flashes
Flashes
Flashes
On
On
On
On
On
On
Off
Off
Off
Off
On
On
On
On
X
1)
X
2)
On
On