Current consumption and power loss of the SINAUT ST7 TIM and modem components
Short module name
TIM 3V-IE
TIM 3V-IE Advanced
TIM 4R-IE
TIM 32
TIM 33
TIM 34
TIM 4V
TIM 4VD
TIM 4R
TIM 4RD
TIM 42
TIM 42D
TIM 43
TIM 43D
TIM 44
TIM 44D
MD2
MD3
MD4
MD740-1
MD720-3
*) only when the TIM module is installed as a CP in an S7-300 rack
**) lower value: Receive mode/ higher value: Send mode
Example
An S7-300 is configured with the following modules:
● 1 power supply PS 307; 2 A
● 1 CPU 314
● 2 digital input modules SM 321; DI 16 x DC 24 V
● 1 relay module SM 322; DO 8 x AC 230 V/5 A
● 1 analog input module SM 331; AI 8 x 12 bits
● 1 analog output module SM 332; AO 2 x 12 bits
● 1 communications module TIM 42
● 1 modem MD3
SINAUT ST7 Station control system - System Manual
System Manual, 05/2007, C79000-G8976-C178-06
3.3 Current consumption and power loss of the SINAUT ST7 components
Module order no.
Current consumption
6NH7 800-3BA00
6NH7 800-3CA00
6NH7 800-4BA00
6NH7 800-3AA20
6NH7 800-3AA30
6NH7 800-3AA40
6NH7 800-4AA00
6NH7 800-4AD00
6NH7 800-4AA90
6NH7 800-4AD90
6NH7 800-4AA20
6NH7 800-4AD20
6NH7 800-4AA30
6NH7 800-4AD30
6NH7 800-4AA40
6NH7 800-4AD40
6NH7 810-0AA20
6NH7 810-0AA30
6NH7 810-0AA40
6NH9 740-1AA00
6NH9 720-3AA00
Current consumption
from backplane bus
from 24 V load power
(max.)
200 mA
200 mA
200 mA
60 mA
60 mA
60 mA
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
60 mA *)
-
-
-
-
-
Power loss (nominal)
supply
160 mA
160 mA
170 mA
300 mA
400 mA
300 mA
400 mA
400 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
100 mA
200 mA
100 mA
320 mA
50 / 140 mA **)
Installation guide
5.8 W
5.8 W
4.6 W
7.5 W
9.9 W
7.5 W
9.9 W
9.9 W
12.3 W
12.3 W
12.3 W
12.3 W
12.3 W
12.3 W
12.3 W
12.3 W
2.4 W
4.8 W
2.4 W
8 W
5 W