Operation Manual / Power2 340-H / Low-pressure stage
3 Removal and installation / 3.2 Removing the low-pressure stage
If present:
Unplug the plug to the speed sensor (86505) and secure the rolled-up cable (2 m) on the
u
low-pressure or high-pressure stage. This protects the plug from being crushed.
Depending on the version of the bracket (04), a pin (03) may have been inserted to ensure
the safe assembly of the low-pressure stage. Therefore always remove the low-pressure
stage from and install it on the bracket vertically.
Fig. 12: Removing the low-pressure stage
1. Attach the lifting gear to the suspension eye and additionally loop it around the gas out-
let casing (61001).
2. Loosen and remove the fixing screws (01) and the fixing screws (05) on the sup-
port (61300).
3. Remove the low-pressure stage vertically.
4. Cover the oil connections (02) in the bracket (04) to protect them from dirt.