Malfunctions During Operation; Table 22: Malfunctions During Operation - Lubricating Oil Pressure Too Low; Table 23: Malfunctions During Operation - Power2 Lp Speed Reductions; Table 24: Malfunctions During Operation - Power2 Hp Speed Reductions - ABB PT003888 Operation Manual

Table of Contents

Advertisement

Operation Manual / Power2 340-H / Low-pressure stage
8 Troubleshooting / 8.2 Malfunctions during operation
8.2

Malfunctions during operation

Lubricating oil pressure too low
Possible causes
Engine
Oil filter heavily contaminated
Oil pump in lubricating system de-
fective
Manometer displays incorrectly
Low-pressure
Axial clearance of the rotor excessive Contact a Turbo Systems service sta-
or
high-pressure
stage
Table 22: Malfunctions during operation – Lubricating oil pressure too low
Drop in low-pressure stage speed
Possible causes
Engine
Defects on the connected cylinders Contact enginebuilder
Low-pressure
Heavy contamination of the tur-
stage
bine
Damaged rotor components or
bearing
Change of operating state of high-
pressure stage
Pipes
Defects, such as leaks, in the ex-
haust gas pipes or charge air ducts
Table 23: Malfunctions during operation – Power2 LP speed reductions
Drop in high-pressure stage speed
Possible causes
Engine
Defects on the connected cylinders
High-pressure
Heavy contamination of the turbine
stage
Damaged rotor components or bear-
ing
Change of operating state of low-
pressure stage
Pipes
Defects, such as leaks, in the exhaust
gas pipes or charge air ducts
Table 24: Malfunctions during operation – Power2 HP speed reductions
Increase in low-pressure stage speed
Possible causes
Low-pressure
Heavy contamination of the nozzle
stage
ring
Table 25: Malfunctions during operation – Power2 LP speed increases
© Copyright 2022 ABB. All rights reserved.
Remedy
Clean
Check/replace
Replace manometer
tion
Remedy
Clean
Contact a Turbo Systems service sta-
tion
Check the operating point of the high-
pressure stage.
Repair
Remedy
Contact enginebuilder
Clean
Contact a Turbo Systems service sta-
tion
Check the operating point of the low-
pressure stage.
Repair
Remedy
Contact a Turbo Systems service sta-
tion
HZTL4053_EN
Rev.F
March 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power2 340-h44

Table of Contents