OPTIONAL CONTROLS
Some units may not have the following items to test
13. Meter
For the following test fill the kettle 3/4 full of water. Have the mixer rotating with the speed
control setting at three to five.
14. Heating Manual
15. Cooling Manual
16. Heating Automatic (Heat/Off/Cool) switch in "Off" position. Open manual steam valve. Follow
17 Chart Recorder
Complete this test using markings on mixer arm or a measuring strip if there are no
markings on the unit. Test the meter at the following values up to capacity (Should be
approx. ± 1/4"). During this test check that the (interrupt) switch stops the water flow
and the (continue/reset) when switched to "continue" resumes the flow without resetting
the meter.
GALLONS
5
20
40
80
100
When the (continue/reset) switch is turned to "reset" the displayed quantity on the
meter should be erased and the count begins at zero.
(Active/Bypass) switch in "Bypass" position. (Heat/Off/Cool) switch in "Heat"
position. Open manual steam valve, steam enters kettle and condensate escapes
from steam trap.
For units equipped with water cooling -
1 1 . . / / Automatic drain opens and discharges water from jacket,
2 2 . . / / Automatic drain closes when steam starts exiting,
3 3 . . / / Condensate drain opens and discharges hot water.
Close manual steam valve and you should hear steam entering kettle slow to a
stop.
Turn (Heat/Off/Cool) switch to "Off". Open manual steam valve. Turn
(Heat/Off/Cool) switch to "Cool". Cooling water enters kettle from large console and
exits from side console.
operating instructions on label to set the temperature to 180°F/ 90°C. Turn
(Active/Bypass) switch to "Active", you should hear steam entering kettle and
condensate should escape steam trap.
For units equipped with water cooling -
1 1 . . / / Automatic drain opens and discharges water from jacket,
2 2 . . / / Automatic drain closes when steam starts exiting,
3 3 . . / / Condensate drain opens and discharges hot water.
a a ) ) Seal chart recorder on the inside all around to the panel with silicone.
b b ) ) Seal pipe penetration where cables enters panel from console with silicone all
around.
LITERS
20
80
160
320
400