ADVANCED OPERATION GUIDE
Pressing
or
change the serial parameter, press [OK] ([ENTER]). Use
change the value or selection.
>Baud Rate
9600
>Data Bits
8
>Stop Bits
1
>Parity
None
>Protocol
DTR(pos.)&XON
For example, to change baud rate from
9600 to 115200, display the baud rate
menu following the above procedure. When
the display shows baud rate, 9600 (bps),
press [OK] ([ENTER]). A blinking question
mark (?) appears.
7
Press
or
to scroll through values. When 115200 is displayed, press
[OK] ([ENTER]). Press [MENU] to exit the menu selection.
NOTE:
Some computers may not be able to handle a baud rate of
115200 bps. If you set the baud rate to 115200 and encounter
communication problems, select a lower baud rate.
toggles through the serial parameters as follows. To
1200, 2400, 4800, 9600 (Default),
19200, 38400, 57600, 115200
7 or 8 (Default)
1 (Default) or 2
None (Default), Odd, Even, or Ignore
DTR(pos.)& Xon (Default),
DTR(positive), DTR(negative),
XON/XOFF, or ETX/ACK
Using the Operator Panel
or
to
Range
>Baud Rate
?
9600
2-31