11 VP-727xl Communication Protocol

This addendum includes the Communication Protocol for the VP-727xl:
Set and Get command:
Set Command:
Y Control_Type Function Param 1 ..... Param N CR
Reply:
Z Control_Type Function Param 1 ..... Param N CRDoneCR
Get Command:
Y Control_Type Function CR
Example
1.
"Y 0 45 32 CR" -> set Preview Contrast value as 32
"Z 0 45 32 CR"
">CR" --> command setting success
2.
"Y 1 78 CR" -> get current Preview output resolution
"Z 1 78 2 CR" -> current Preview resolution is 832x624
Definition:
: ASCII Code 0x20
CR: ASCII Code 0xD or 0xA
After set type Command setting, system will respond with a string.
Baud rate: 115200bps, Start Bit: 1Bit, Data Bit: 8Bit, Parity Bit: NA, and
Stop Bit: 1Bit.