Sharp AR-M350U Service Manual page 216

Options ar-p14
Hide thumbs Also See for AR-M350U:
Table of Contents

Advertisement

66-33
Purpose
Setup
Function (Content)
Used to check signal detection.
Section
FAX
Item
Operation
Operation/Procedure When the signal is detected, the display is
highlighted.
<This mode is for development, and inhibited in the market.>
SIMULATION 66-33
SIGNAL DETECT CHECK.
BUSY TONE
CNG
CED
FNET
66-34
Purpose
Setup
Function (Content)
Used to measure and display the communication
time.
Section
FAX
Item
Operation
Operation/Procedure The time spent for communication is measured.
Send/receives performed in the normal mode.
The communication time is displayed with the
simulation. (unit: ms)
SIMULATION 66-34
COMMUNICATION TIME DISPLAY.
***** ms
<Setup for send>
Communication means
Image quality
Density
ECM
Sender record
66-35
Purpose
Operation test, check
Function (Content)
Modem program rewriting.
Section
FAX
Item
Operation
Operation/Procedure The modem program in the FAX program is
rewritten.
1) Select with 10 digit key pad and press START
to execute the following.
1: MODEM program rewrite
2:Not clear
2) Check the check sum value (loader).
If it is OK, the test is normally completed.
If NG, the check sum value
(1 byte = hexadecimal) is displayed.
3) If the check sum value is NG, the MODEM
result is also NG.
4) The Modem rewrite result is displayed.
DTM
memory transmission
Normal
Thin
ON
OFF
AR-M350 SIMULATIONS 10-72
SIMULATION 66-35
MODEM PROGRAM RELOAD.
ARE YOU SURE ?
1. YES
2. NO
Press [START] key.
SIMULATION 66-35
MODEM PROGRAM RELOAD. EXECUTING...
LOADER...(OK or Check Sum value 1 byte (hexadecimal))
MODEM...(COMPLETE or NG code 1 byte (Hexadecimal))
After completion of writing
SIMULATION 66-35
MODEM PROGRAM RELOAD.
LOADER...OK
MODEM...COMPLETE
<Result of MODEM writing>
COMPLETE
81
82
83
84
NG
66-36
Purpose
Operation test, check
Function (Content)
Used to check interface between MFPC and
MDMC. Check is made in the data line or the
command line.
Section
FAX
Item
Operation
Operation/Procedure 1) Select with 10 digit key pad and press START.
2) When check is "repeat,"
executed until the result becomes NG or
CUSTOM SETTING is pressed.
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MFPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
Press [START] key.
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...
When check is "once" or "repeat"
and the result is NG
SIMULATION 66-36
MFPC-MDMC I/F CHECK . INPUT 1-8, AND PRESS START.
EXECUTING...(OK or NG)
<List of display values>
1
MFPC <- MDMC
2
MFPC -> MDMC
3
MFPC <- MDMC
4
MFPC -> MDMC
5
MFPC <- MDMC
6
MFPC -> MDMC
7
MFPC <- MDMC
8
MFPC -> MDMC
1
Writing completed
Check sum error
Write error
Delete error
Verify error
Due to loader error
the operation is
1
1
When check is "repeat" and
[CUSTOM SETTING] key is pressed.
Data line once only
Data line once only
Data line repeat
Data line repeat
Command line once only
Command line once only
Command line repeat
Command line repeat