Sharp AR-M350U Service Manual page 157

Options ar-p14
Hide thumbs Also See for AR-M350U:
Table of Contents

Advertisement

3-tray desk
MCSS3
MP tray size detection 3
MCSS2
MP tray size detection 2
MCSS1
MP tray size detection 1
MCSPD
MP tray remaining quantity
detection
MCLUD
MP tray upper limit
detection
MCPED
MP tray paper empty
detection
DPFD1
MP tray transport detection
4-3
Purpose
Operation test, check
Function (Content)
Used to check the operation under load in the
paper feed section (desk paper feed/large
capacity trays) and their control circuits.
Section
Paper feed
Item
Operation
Operation/Procedure Select with 10 digit key pad.
SIMULATION 4-3
DESK/LCC LOAD TEST. SELECT 1- , AND PRESS START.
1.
2.
Press [START] key to get started.
SIMULATION 4-3
DESK/LCC LOAD TEST. EXECUTING...
1.
2.
<List of set values>
3-tray desk
1 DLUM2 Desk lift-up motor 2
2 DLUM1 Desk lift-up motor 1
3 MCLUM Desk multi lift-up
motor
4 DPFCL Desk paper transport
clutch
5 DPCL2
Desk paper feed
clutch 2
6 DPCL1
Desk paper feed
clutch 1
7 MCPCL Desk multi paper feed
clutch
8 DMM
Desk transport motor
LCC
2
Press [CUSTOM SETTING] key to stop.
2
LCC
1 TLUM2 LCC lift-up motor 2
2 TLUM1 LCC lift-up motor 1
3 MCLUM LCC multi lift-up
motor
4 TPFCL
LCC transport clutch
5 TPCL2
LCC paper feed
clutch 2
6 TPCL1
LCC paper feed
clutch 1
7 MCPCL LCC multi paper feed
clutch
8 TMM
LCC transport motor
AR-M350 SIMULATIONS 10-13
Main code 5
5-1
Purpose
Operation test, check
Function (Content)
Used to check the operations of the lamps and
LCD on the operation panel and their control
circuits.
Section
Operation (display, operation)
Item
Operation
Operation/Procedure All LEDs are ON. The LCD contrast changes
Max/Min every 2sec.
SIMULATION 5-1
After 6.0 sec
SIMULATION 5-1
5-2
Purpose
Operation test, check
Function (Content)
Used to check the operations of the heater lamp
and its control circuit.
Section
Fusing
Item
Operation
Operation/Procedure Select with 10 digit key pad. The lamp repeat
ON/OFF every 500ms 5 times.
SIMULATION 5-2
HEATER LAMP TEST. SELECT 1-2, AND PRESS START.
1.HL1(LOWER)
2.HL2(UPPER)
Press [START] key to get started.
SIMULATION 5-2
HEATER LAMP TEST. EXECUTING...
1.HL1(LOWER)
2.HL2(UPPER)
<List of set values>
1
Heater lamp 1 (Lower)
2
Heater lamp 2 (Upper)
Press [CUSTOM SETTING] key to stop.
2
Press [CUSTOM SETTING] key to stop.
Repeats specified times and stops.
2