66-13
Purpose
Setup
Function (Content)
Used to select the FAX dial signal output test.
(The dial number signal set with this simulation
is outputted in the dial signal output test with
SIM 66-14~16)
(Only when FAX is installed.)
Section
FAX
Item
Data
Operation/Procedure The dial test number is set.
Enter a number with 10 digit key pad, * key, and
# key.
The upper limit is 20 digits.
Press CLEAR to return to the initial state.
Press START to register.
SIMULATION 66-13
DIAL TEST NUMBER SETTNG.
INPUT NUMBER AND PRESS START.
0123456789*#01234567
66-14
Purpose
Setup
Function (Content)
Used to set the add time to the FAX pulse dial
mode (10PPS) and to test the dial signal output.
(The dial number signal set with SIM 66-13 is
outputted.)
Used to check dialing troubles and the operation.
(Only when FAX is installed.)
Section
Fax
Item
Operation
Operation/Procedure The dial test is performed. (10PPS output)
The make time is set.
When CUSTOM SETTING is pressed, the
execution is terminated.
SIMULATION 66-14
DIAL TEST(10PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
; [
ms]
7
+29
1.MAKE TIME
Select 0 and
Select 1 and press [START] key. Press [CUSTOM SETTING] key
press [START] key.
SIMULATION 66-14
DIAL TEST(10PPS). SELECT 0-15, AND PRESS START.
[1.MAKE TIME]
SIMULATION 66-14
DIAL TEST(10PPS). EXECUTING...
; [
ms]
7
+29
1.MAKE TIME
<List of set values>
0
Execution
1
Dial pulse make time setup (0 - 15)
*
Dial is send with the setup value of +29ms.
0-9:[0-9], *[*], #:[ ]
#
1
1
or [START] key.
7
Press [CUSTOM SETTING] key.
AR-M350 SIMULATIONS 10-67
66-15
Purpose
Setup
Function (Content)
Used to set the add time to the FAX pulse dial
mode (20PPS) and to test the dial signal output.
(The dial number signal set with SIM 66-13 is
outputted.)
Used to check dialing troubles and the operation.
(Only when FAX is installed.)
Section
Fax
Item
Operation
Operation/Procedure The dial test is performed. (20PPS output)
The make time is set.
When CUSTOM SETTING is pressed, the
execution is terminated.
SIMULATION 66-15
DIAL TEST(20PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
; [
+9
ms]
7
1.MAKE TIME
Select 0 and
Select 1 and press [START] key. Press [CUSTOM SETTING] key
press [START] key.
SIMULATION 66-15
DIAL TEST(20PPS). SELECT 0-15, AND PRESS START.
[1.MAKE TIME]
SIMULATION 66-15
DIAL TEST(20PPS). EXECUTING...
; [
ms]
7
+9
1.MAKE TIME
<List of set values>
0
Execution
1
Dial pulse make time setup (0 - 15)
*
Dial is set with the setup value of +19ms.
1
or [START] key.
7
Press [CUSTOM SETTING] key.

Advertisement