66-5
Purpose
Operation test, check
Function (Content)
Used to check the operations of data signal
output in the FAX data output mode.
(Used to check the MODEM operation.)
Signals are sent in the send level set with the
soft switch. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure Signal output check
(Send level is set with the soft SW.)
When CUSTOM SETTING is pressed during
execution of this simulation,
execution is stopped.
Enter a number and press START to change the
kind of signal.
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
Press [START] key.
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
Same
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
display
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
Select 2 and press [START] key.
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
EXECUTING...
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.) SELECT 1-32, AND PRESS START.
1.NOSIGNAL 2.33.6 V34 3.31.2 V34 4.28.8 V34
5.26.4 V34 6.24.0 V34 7.21.6 V34 8.19.2 V34
9.16.8 V34 10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34 14.4.8 V34 15.2.4 V34 16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17 22.9.6 V29 23.7.2 V29 24.4.8 V27t
25.2.4 V27t 26.0.3 FLG 27.CED 2100 28.CNG 1100
29.0.3 V21 30.ANSam 31.RINGER 32.No RBT
1
Press [CUSTOM SETTING] key.
1
2
Press [CUSTOM SETTING] key.
2
AR-M350 SIMULATIONS 10-63
<List of set values>
1
No signal
2
33.6 V34
3
31.2 V34
4
28.8 V34
5
26.4 V34
6
24.0 V34
7
21.6 V34
8
19.2 V34
9
16.8 V34
10
14.4 V34
11
12.0 V34
12
9.6 V34
13
7.2 V34
14
4.8 V34
15
2.4 V34
16
14.4 V33
66-6
Purpose
User data output, check (display, print)
Function (Content)
Used to print the confidential password.
(Used when the confidential password is
forgotten.) (Only when FAX is installed.)
Section
Fax
Item
Data
Operation/Procedure The confidential pass code is printed.
1) The currently selected data is displayed on
the side of menu.
2) The paper size is automatically selected by
the size stored in the image memory.
SIMULATION 66-6
PASS CODE PRINT OUT. PRESS START
1. PRINT START
Select 1 and
press [START] key.
If there is no data to print,
return without printing.
SIMULATION 66-6
PASS CODE PRINT OUT.EXECUTING...
1. PRINT START
After completion of printing
<Set value>
1
Print start
17
12.0 V33
18
14.4 V17
19
12.0 V17
20
9.6 V17
21
7.2 V17
22
9.6 V29
23
7.2 V29
24
4.8 V27t
25
2.4 V27t
26
0.3 FLG
27
CED2100
28
CNG1100
29
0.3 V21
30
ANSam
31
RINGER
32
No RBT
0